Skip to content

Safety Information ​

The AuboStudio enables the configuration of numerous safety features of the AUBO robot, such as safety I/O interfaces, along with additional electrical interfaces for connecting to various devices and protective devices. All safety features and I/O interfaces are designed according to ISO 13849-1:2015 (PL=d, CAT 3). The power and force limitation safety features meet the impact force limit requirements in ISO/TS 15066-2016, with the force value lower than the maximum thresholds specified for transient and quasi-static contact between humans and robots. The network communication functions meet the cybersecurity requirements of ISO 10218-1:2025.

Safety instructions ​

Danger

"Danger" indicates a highly dangerous situation that, if not avoided, could result in serious injury or death.

Warning

"Warning" indicates a dangerous situation that, if not avoided, could result in injury.

Tip

"Tip" indicates a potential risk of equipment damage or data loss.

Info

"Info" indicates information that requires special attention.

Personnel safety ​

Before entering the working area of robot, ensure that all safety rules are strictly followed.

Please remain vigilant at all times and ensure your own safety!

Safety rules ​

To ensure the safe operation of the robot and personal user safety, adherence to the following safety guidelines is mandatory:

  1. Please familiarize yourself with the operating procedures and safety information related to the hardware prior to use.
  2. When the robot is operational, do not stretch your hands or other objects into the robot's operational area to prevent potential injury.
  3. Before activating the robot power supply, please ensure the surrounding area is safe and free from any obstacles, which could interfere with robot operation.
  4. In the event of an abnormal operation or unusual noises, please stop the robot immediately and contact the technical support team for inspection and maintenance.

Adhering the above safety guidelines will ensure safety operation of robot to the greatest extent possible, while also protect the personal safety of the user.

Network security ​

AuboStudio supports network protocols such as TCP/IP, VNC, and X, as well as industrial fieldbus protocols such as Modbus TCP, PROFINET, and EtherNet/IP. The system's core operation does not depend on the external Internet and functions normally while offline.

Tip

  • TCP/IP: The system's basic networking and communication protocol.
  • VNC: A remote desktop protocol that transmits data in plaintext by default. Use it only on trusted intranets, and never expose it to external networks.
  • X: A graphical remote forwarding protocol that is unencrypted by design. Use it only on isolated intranets.
  • Modbus TCP, PROFINET, and EtherNet/IP: Industrial fieldbus protocols without native encryption or authentication, used for I/O interaction and motion synchronization between the robot and devices such as PLCs and servo drives. They must be deployed on an independent, isolated industrial control subnet and must never be connected to an external network or mixed with an office network. For details, see Fieldbus.

Network architecture and environment requirements ​

Before using network functions, users must understand the device deployment environment and conduct a network security risk assessment.

  • Network environment requirements: Deploy the device on a controlled industrial network or an isolated network segment.
  • Access control requirements: Allow only authorized devices to access necessary control interfaces, and avoid exposing control interfaces directly to the public Internet.
  • Secure transmission: When downloading software installation packages over the network, the system enforces HTTPS encrypted transmission.
  • Peripheral and component security: When connecting external hardware, such as PLCs or USB flash drives, make sure it is secure and compliant. USB flash drives carrying the preceding data must be properly protected. Open-source tools used in the system have passed security evaluation and are pinned to fixed versions; dynamic upgrades are not supported, thereby avoiding uncontrollable risks.

Tip

  • The core functions of AuboStudio support fully offline operation. To access AuboStudio wirelessly, deploying a local LAN is sufficient.
  • AuboStudio needs an Internet connection only for the [Software Update] function; installation packages can also be uploaded offline, so an Internet connection is optional.

Security operation recommendations ​

  1. Identity authentication: Enable SSH access and key authentication only when remote device maintenance is necessary. Allow only authorized personnel to connect through controlled terminals and secure clients, and never expose SSH directly to the public Internet. Disable the SSH service promptly after maintenance. For the procedure, see Enabling SSH access.
  2. Environment discipline: Operate the server with caution. Avoid downloading unverified software or performing unconventional operations, prevent the spread of malicious software, and keep the server environment clean and standardized.
  3. External network control: If the LAN to which the robot is connected is connected to an external network, identity control authentication must be enabled in the firewall to strictly prevent unauthorized access.

Built-in static security mechanisms ​

The system provides basic security protection that does not rely on user intervention:

  • Password verification: When modifying features that involve safety risks, such as equipment safety and personal safety, the software forces verification of the corresponding password.
  • Security prompt: The software has no default password at the factory. Set a strong password immediately after device deployment. For the procedure, see Authority - Classic mode.
  • Installation package verification: Installation packages of the software and firmware use SHA-256 and MD5 digest verification. The system verifies integrity during installation and rejects installation if verification fails.

Advanced security restrictions (enable as needed) ​

The system provides stricter security control capabilities. The following features are disabled by default and can be enabled manually according to business security requirements:

  • Network firewall whitelist: After configuration, only the IP addresses or subnets in the list can access the device, and port-level restrictions are not supported. For port access control, enable or disable services individually through Communication Service Management. For the procedure, see Security - Whitelist.
  • Advanced authority system: Supports access control based on the [Role] and [User Permission] system. For advanced mode settings, see Authority - Advanced mode.

User security responsibilities and incident response ​

  • Deploy this product in a controlled industrial network environment. Users must implement network isolation, access control, and endpoint security measures based on the on-site network architecture.
  • Do not expose robot control interfaces directly to the public Internet. Enable only communication services required for business operations.
  • If abnormal access, communication anomalies, or other network security incidents that may affect safe robot operation are detected, stop the robot immediately in accordance with the equipment safety procedures.
  • After shutdown, isolate the affected network and promptly contact the manufacturer for support.

Password security ​

In the interest of ensuring operational safety, the software has been designed to incorporate a password setting function. Users are able to manage and control different operations through the setting of distinct passwords. Please refer to Authority - Classic mode for further information.

To ensure optimal password security, please follow these recommendations:

  1. Set a complex password that contains upper/lower-case letters, numbers, and special characters, and avoid using common words or personal information.
  2. Passwords should ideally have a minimum of 8 characters, since longer passwords are more difficult for others to guess.
  3. To avoid unexpected disclosure of password, set a unique password for each operation, and do not share a password for two or more operations.
  4. To reduce the risk of password guessing or cracking, it is advisable to change passwords every three months.

Tip

Please keep Admin password in mind. The system does not support password recovery functionality. If you forget the password, you may be unable to use the device. Furthermore, it is imperative to safeguard your password from unauthorized access.